KINGSPAN TF70 PDF

Kingspan Therma TF70 Floorboard; high performance insulation for floors with a continuous thermal performance, lasting a constructions life cycle. Kingspan TF70, TW55 and TP10 are readily available in the following product thicknesses 20mm, 25mm, 30mm, 40mm, 50mm, 60mm, 70mm, 75mm, 80mm. Thermafloor TF70 is a high performance, fibre free, rigid thermoset insulation core faced on both sides with a low emissivity composite foil facing which is used .

Author: Nilkis Nik
Country: Venezuela
Language: English (Spanish)
Genre: Health and Food
Published (Last): 5 February 2015
Pages: 52
PDF File Size: 2.40 Mb
ePub File Size: 1.5 Mb
ISBN: 480-3-40013-866-9
Downloads: 83973
Price: Free* [*Free Regsitration Required]
Uploader: Goltiktilar

Method of test to determine the classification kimgspan the surface spread of flame of products Result – Class 1 rating.

To comply with NHBC recommendations, preservative treated softwood timber battens should be positioned at doorways, access panels and to support partitions. Contact our experienced technical services department today.

Therma TF70 Floorboard

Before the timber floor boards are interlocked, apply a continuous kingspqn of waterproof wood grade PVA adhesive to the top and bottom of the tongue and groove joints. All board joints should be tightly butted. Pannal Water Tower Products from our Kooltherm and Therma ranges have helped to transform a derelict water tower in North Yorkshire into a striking family home.

Click for more information. Do you need help or advice on a project?

The Lynn Building at Queens University Belfast Architects Consarc Conservation in Belfast worked closely with the main contractor Woodvale Construction Company to bring life back to kinbspan wonderful building which has been vacant since Ensure that insulation boards are fitted tightly between the joists, and any gaps are filled with expanding urethane sealant. Construction work started immediately and was completed in with the official opening taking place on May 2nd t70 Kingspan TF70 75mm, 4 x 1.

  BARTONELOSIS PERU PDF

Ensure battens are of the appropriate thickness, so that the insulation boards finish flush with their top surface unless an underfloor heating system is to be used. Kingspan TF70 mm, 3 x 1.

Underfloor Heating Systems Please refer to the instructions of the specific underfloor heating system manufacturer. Use sand and cement screed laid to a minimum thickness of 65 mm for domestic construction and 75 mm elsewhere.

If two layers of insulation are required, they should be horizontally offset relative to each other so that, as far as possible, the board joints in the two adjacent layers do kingdpan coincide with each other. Fairways A range of premium and high performance products has been installed on a stunning new beachfront home on the Isle of Wight, featured on Grand Designs. Adhesives containing such solvents should not be used in association with this product.

Measure the distance between the battens prior to cutting the boards as spacings can vary. Ensure the polythene sheet has mm overlaps, taped at the joints, and is turned up mm at the walls. Concrete slabs should be t7f0 to dry out fully prior to the installation of Kingspan Thermafloor TF70 average 1 day per mm of slab thickness.

Kingspan Thermafloor TF70 is not suitable kngspan installation directly over timber joists. The kingspna core is not resistant to some solvent—based adhesives systems, particularly those containing methyl ethyl ketone.

  ACCESS 2007 DOCMD.OUTPUTTO PDF

TF70 | Floor Insulation | Kingspan | Ireland

Installation Below a Floor Screed Concrete slabs should be allowed to dry out fully prior to the installation of the insulation boards average 1 day per mm of slab thickness. Side—nail 25 mm x 25 mm timber battens to the joists or partially drive galvanised nails into the side of the joists in the appropriate position to hold the boards in place. Thermafloor TF70 Download Download.

Order before 10am for next working day delivery. Specifications Useful links Case Studies.

Floor insulation | Thermafloor TF70 | Kingspan | Great Britain

Bree Industrial Estate Castleblayney Co. Please click “Accept and close” to accept the use of cookies on our website.

Once the timber floor boards have been laid, temporary wedges should be inserted between the walls and the floor, to maintain tight joints, until the adhesive has set. These boards are faced on both sides with a low emissivity composite foil facing that is highly resistant to the transmission of water vapour. The subsequent installation of the concrete slab and screed or other flooring material is carried out in a manner similar to that for an un—insulated floor.

Please observe the ‘Star Rating’ indicators to assess availability. A thin sand blinding may be used to achieve a continuous level surface free from projections kibgspan rolled hardcore. It used to insulate solid concrete and suspended timber ground floors, and has a thermal conductivity of 0.